Skip to content

FMS-FCU-1315

productos-fcu

FMS-FCU-1315

PREVENTIVE MAINTENANCE
MAXIMUM EFFICIENCY

DESCRIPTION
The FCU 1315 is a portable service unit and is designed for temporary measurement of solid particle contamination and water saturation in diesel storage, diesel transfer and diesel filling applications. Measuring contamination levels of diesel fuel, as well as mineral based hydraulic oils compatible with Viton® seals. The FCU 1315 is not compatible with water glycol fluids.
TECHNICAL SPECIFICATION
Self-Diagnosis Continuously with error indication via status LED and display
Measured Value ISO code / SAE Class / NAS Class / Saturation Level / Temperature
Measuring Range  Display from ISO code 9/8/7 (MIN) to ISO code 25/24/23 (MAX)
  Calibrated within the range ISO 13/11/10 to 23/21/18
  Saturation level 0 to 100 % /
Temperature -13°F to 212°F (–25°C to 100°C)
Accuracy ± 1/2 ISO class in the calibrated range / ± 2 % Full scale max
for Water Sat. and Temp.
Material of Sealings FPM seals
Ambient Temperature Range 32°F to 113°F (0°C to 45°C)
Storage Temperature Range -40°F to 176°F (-40°C to +80°C)
Dimensions (cover closed) 9.06” H x 16.14” L x 13”D
IP Class IP50 in operation, IP67 when closed
Weight Approx. 29 lbs (13 kg) without accessories
With Diesel According to IN: 0 psi (0 bar)
ASTM D975 4-D or DIN EN 590 OUT: 0 psi (0 bar)
HYDRAULIC DATA
Hydraulic Fluid IN: -7.25 to 650 psi (-0.5 to 45 bar)
Operating Pressure OUT: 0 to 7.5 psi (0 to 0.5 bar)
with Adapter for Pressure Lines IN: 217 to 5000 psi (15 to 345 bar)
  OUT: 0 to 7.5 psi (0 to 0.5 bar)
Pressure Max. 5000 psi (345 bar)
Permissible Viscosity Range 33 to 1622 SUS (1.5 to 350 cSt)
Fluid Temperature Range 32°F to 158°F (0°C to +70°C), or up to 113°F (45°C) for diesel fuel

ELECTRICAL DATA

Power Supply Voltage 24 VDC ± 20%, residual ripple < 10%
Max. Power/Current Consumption 100 Watt / 4 A
Interface Plug connection, 5-pole, male, M12x1 and USB

Related Products