CONTAMINATION CONTROL
AT DISPATCH
DESCRIPTION
Water and emulsions cause up to 15% of power loss, thus up to 15% increase in fuel consumption. All ISO 4406 contamination control plans must contemplate water and emulsions with SAE J1488 certified systems.
HOUSING TECHNICAL SPECIFICATION
Max. Flow per Housing | 25 gmp |
Porting | 1 1/4″ NPT |
Additional Ports | 4 x 1/8″ NPT (2 x US & 1 DS) |
Elements Options | FMS-1/25-P (particulate) |
FMS-W25-A (absorbing) | |
Max. Operating Pressure | 100 psi (7 bar) |
Min. Yield Pressure | 150 psi (10 bar) |
Temperature Range | -20ºF to 225º (-29ºC to 107ºC) |
Bypass Setting | 30 psi (2 bar) |
Porting Base | Cast Aluminum |
Element Case | Steel |
Element Change Clearance | 2.5″ (65 mm) |
Weight | 5 lbs (2.3 kg) |
ELEMENT TECHNICAL SPECIFICATION
Efficiency | 95% |
WHCÂ | 1000 ml |
Maximum Flow | 40 gpm |
Recommended Flow | 25 gpm |
Dimensions | 10 x 5 x 5″ |
Weight | ND lbs |
Housings | FMS-25-BP |