Skip to content

FMS-350-BP

productos-350-bp

FMS-350-BP

LESS FUEL CONSUMPTION
MORE HORSEPOWER

DESCRIPTION
FMS Filtering Systems has proven in the field to deliver Ultra-clean Ultra-dry diesel with better than ISO 11/8/7 fuel cleanliness levels, under harsh operating conditions, in a single pass, resulting in maximum engine power with a perfect performance.
HOUSING TECHNICAL SPECIFICATION
Max. Flow per Housing  350 gmp
Porting  3″ NPT
Additional Ports  2 x test points,
  2 x manometers,
  1 x Delta P indicator (pop-up or sensor)
Elements Options FMS-1/350-P
Max. Operating Pressure 500 psi (35 bar)
Min. Yield Pressure 2500 psi (172 bar)
Temperature Range -20ºF to 225º (-29ºC to 107ºC)
Bypass Setting 30 psi (40 psi optimal)
Porting Base Cast Aluminum
Element Case Steel
Cap Ductile Iron
Weight 210 lbs
Element Change Clearance 36.8″ (859mm)

ELEMENT TECHNICAL SPECIFICATIONS

Efficiency  Beta 4>4193 (ISO 16889:99)
DHC  3000 grams (MTD)
Maximum Pressure  150 psi
Recommended Flow  350 gpm
Dimensions 42×6.25×6.25”
Weight 21 lbs
Housings FMS-350-BP

Related Products